This full depth 3U rack unit offers 8 sequentially controlled outputs with a host of other features. The input is via Neutrik PowerCon and the Sequence has a front panel mounted 20A circuit breaker which also provides main power isolation.
The outputs are powered on or off sequentially when the unit is triggered. The delay is adjustable in four groups with dip switches on the rear panel. The Sequence can be triggered on or off in any or all of three ways. Firstly, a front panel rocker switch. Secondly a remote switch contact or thirdly by opto isolated voltage source. The last two options are connected by a 4 pin XLR connector on the rear panel. All of the triggers may be used uniquely or together.
Whilst the Sequence has 8 power outputs there are a further 4 channels of "slave outputs". These are available on a 5 pin XLR connector on the rear panel. These can either trigger other Sequences via their control input, or drive any of our other controllable products like the AV2, AV8, Grid or slave units.
The Sequence has a blue digital "true RMS" voltmeter on the front panel. This accurately displays the AC line input voltage. However, should the line voltage drop below, or rise above, a voltage deemed to be dangerous to the equipment powered from the Sequence, the outputs will be rapidly powered down. The display will then signal either a "lo" or 'hi" message.
| Number of available outlets: | 8 | |
| Type of outlets available: | 13A British chassis sockets European Shuko | |
| Standard Mains Inlet: | 20A Neutrik PowerCon | |
| Dimensions: | 19 inch, 3U rackmount 445 x 133 x 350mm (W x H x D) plus connectors | |
| Product Weight: |
10.0Kg | |
| Construction: | Steel chassis with Titanium finish Aluminium front panel | |
| Mains Voltage: | 200-260VAC | |
| Maximum Continuous Current: | 20 Amps | |
| Protection: | Double pole circuit breaker | |
| Slave Output Specification | 12VDC @ up to 75mA per channel | |
| Slave Output connector | Neutrik 5 pin XLR female | |
|
Pin 1 |
Common | |
| Control Input Specification: | Trigger 8 to 24 V, AC or DC | |
| Control Input Connector: | Neutrik 4 pin XLR male | |
|
Pin 1 |
} Voltage trigger (opto isolated 8mA max) } Contact trigger | |
© 2008 ISOL-8 Teknologies Ltd. Tel: 020 8856 8856